Tunnel Axial Mining Fans Pumps for Mining Local Ventilation

Product Details
Customization: Available
Material: Mill Steel
Usage: for Ventilation
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (6)
  • Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
  • Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
  • Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
  • Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
  • Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
  • Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
Find Similar Products
  • Overview
  • APPLICATIONS
  • GENERAL SPECIFICATIONS
  • FAN CONSTRUCTIONS
  • PRODUCTION DETAILS
  • PRODUCTION WORKSHOP
  • PRODUCTION&TESTING EQUIPMENT
  • CUSTOMER CASES
  • DELIVERY & PACKAGE WORLDWIDE
Overview

Basic Info.

Model NO.
MTX-TCD
Pressure
Low Pressure
Certification
ISO, CE
Air Volume
300-5000m3/Min
Total Pressure
200-7000PA
Motor Power
5.5-185kw
Speed
740/980/1480rpm
Driven Type
Direct Driven
Running Mode
Uni-Directional and Reversible
Application
Rail/Metro/Road Tunnel/Hydro Electric Power Plant
Control Type
Portal to Portal, Shaft to Shaft and Portal to Sha
Voltage
380V/440V/660V
Frequency
50Hz/60Hz
Electric Current Type
AC
Fan Effect
Smoke Extraction
Dimension
According to Order
Color
Red/White/Grey/Customized
Guarantee Period
One Year
Transport Package
Wooden Case
Specification
Axial Fan for Tunnel
Trademark
Motexo
Origin
China
HS Code
841459
Production Capacity
1000sets Per Month

Product Description

 

Motexo Vent--

Jet Fan for Tunnel Ventilation

 
APPLICATIONS
 

GSF series jet fans operating in this series of tunnels are mainly used for longitudinal jet ventilation
of traffic tunnels such as roads and railways. 

 

GENERAL SPECIFICATIONS

 

The high-speed jet airflow generated by jet fans promotes airflow direction in the
tunnel to achieve ventilation and ventilation. The purpose of rehearsal can be achieved.
The medium to be transported is air, the ambient temperature is between -25 °C and 50 °C,
the content of dust and other solid impurities in the medium is not more than 150 mg/m3,
and there is no viscosity, five fiber materials.

 

The main features of the fan are corrosion resistance, high-temperature resistance, no breakage,
no oxidation, fast wind and customs, two winds, and low noise.

The reversible jet fan is ventilated in both directions and can ventilate and exceed 98% of the forward
Ventilation when reverse venting is used to ensure the tunnel is filled with fresh air.
The GSF jet fan produced by our company can use the high-efficiency blades developed by our
company or directly install the imported fan blades according to users' needs.
It can also be equipped with two-speed motors according to user needs, which are used for forced
exhaust (smoke) or low-grade ventilation to maintain energy-saving operation.

 

When a fire breaks out in a tunnel, it can run continuously for one hour at an ambient temperature
of 250 °C and half an hour at a temperature of 280 °C. Customized if the user has unique needs.

These jet fans are produced for customers' special requests. If the customer has other
requirements for pressure and air volume that are not included in the following list,
please contact our technicians to design and select the appropriate tunnel fan.

 

FAN CONSTRUCTIONS


FAN CASING

The casing is formed from the Q235 steel sheet to stainless steel SS316 or 304 with integral supports.
After production, the grey/red/white/orange paint finish is applied; optional hot dip galvanization,
furnace paint, or epoxy paint is available. On fan casing, there is Aerodynamical Inlet


STRUCTURE DRAWING


Tunnel Axial Mining Fans Pumps for Mining Local VentilationTunnel Axial Mining Fans Pumps for Mining Local Ventilation
 

IMPELLER

Impellers are produced from Q235 Steel Sheet, stainless steel, ZAlSi7Mn Aluminium.

Static and dynamic vibration defects recovered after production according to appropriate.
ISO/GB norm.
Wheel Size:  400--1800mm

 

Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
 

DRIVEN TYPE
Direct driven

 

OPTIONAL ACCESSORIES

1D/2D Inlet silencer or 1D/2D outlet silencer,flexible connecter.


View more details and technical sheet of our jet fan,kindly contact us to get the latest catalog.
 

IN-HOUSE MANUFACTURING
  • Impellers in fabricated steel construction
  • Fan shaft machining
  • Qualified welding procedures according to GB norms
  • There is virtually no limit to the type of material
 
PRODUCTION DETAILS


Tunnel Axial Mining Fans Pumps for Mining Local Ventilation

Tunnel Axial Mining Fans Pumps for Mining Local Ventilation

 

PRODUCTION WORKSHOP


Motexo Fan manufactures 300 series and more than 1,400 kinds of industrial fans.
All include heavy-duty designs for industrial applications.

We have individual workshops for roots blower,centrifugal fans and blowers,
maintaining,axial fan, welding and assembling.


Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
Tunnel Axial Mining Fans Pumps for Mining Local Ventilation
 

PRODUCTION&TESTING EQUIPMENT


We can produce large batches of small fans and have the processing capability to produce heavy-duty fans above 3.5m high. We adopt the best technology in all aspects of industrial fan,
such as shot blasting, sandblasting, all the paint process, welding process, etc.
Stoving varnish looks brighter than water paint( ordinary painting color). It has more than 200 sets of fine,
large and rare processing equipment, and has a high-tech resin sand casting production line.

Our equipment is generally used for power plants, environmental protection plants, coal plants, etc.
It requires high technology and workmanship.

Tunnel Axial Mining Fans Pumps for Mining Local Ventilation

FACTORY PRODUCTION CAPACITY:
AIRFLOW
SWSI FANS - UP TO 900,000 CFM (1,529,100 M3/HOUR)
DWDI FANS - UP TO 1,500,000 CFM (2,548,500 M3/HOUR)

STATIC PRESSURE
SINGLE-STAGE FANS   - UP TO 120 INCHES W.G. (29,850 PA)
TWO-STAGE FANS        - UP TO 240 INCHES W.G. (59,650 PA)

TEMPERATURE RANGE:  UP TO 1,500°F (815°C)
MOTOR SIZES:  UP TO 15,000 HP (11,185 KW)
ARRANGEMENTS:  1, 3, 7, 8

WHEEL SIZES UP TO 160 INCHES (4,065 MM)

 

CUSTOMER CASES

 

Mining/Metro Line/Tunnel Project Worldwide

We've been working on many projects in Uganda,Indonesia, Myanmar,Peru,Pakistan and
other countries for tunnel&mining projects,sewage treatment projects,Steel plant boiler drafting project
and Hydro Electric Power Plant.
We understand the harsh environments in which fans are used.
Motexo fans will meet and exceed the demands of your industry engineering,
infrastructure projects, mining/tunnel projects, and other environmental projects.

Tunnel Axial Mining Fans Pumps for Mining Local Ventilation

Jet Fan Equipped with Frequency Control Panel/Soft Starter

 

Tunnel Axial Mining Fans Pumps for Mining Local Ventilation

 
DELIVERY & PACKAGE WORLDWIDE

 

For diverse requirements for customers or fans and blowers, we have three methods available
Wooden box, wooden palisade and paper carton.
All packages are passing international exported standards.

Tunnel Axial Mining Fans Pumps for Mining Local VentilationTunnel Axial Mining Fans Pumps for Mining Local Ventilation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier