• Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
  • Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
  • Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
  • Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
  • Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
  • Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

Material: Stainless Steel
Usage: for Ventilation
Flow Direction: Centrifugal
Pressure: High Pressure
Certification: ISO, CE
Air Flow: up to 1, 500, 000 Cfm (2, 548, 500 M3/Hour)
Customization:

Contact Supplier

Gold Member Since 2019

Suppliers with verified business licenses

Trading Company
  • Overview
  • APPLICATIONS
  • GENERAL SPECIFICATIONS
  • FAN CONSTRUCTIONS
  • PRODUCTION DETAILS
  • PRODUCTION WORKSHOP
  • PRODUCTION&TESTING EQUIPMENT
  • CUSTOMER CASES
  • DELIVERY & PACKAGE WORLDWIDE
Overview

Basic Info.

Model NO.
MTX-VTA
Total Pressure
up to 240 Inches W.G. (59, 650 PA)
Motor Power
15-90kw, 1400kw or Higher
Speed
2950rpm
Driven Type
Direct/Belt/Coupling Driven
Running Mode
Uni-Directional and Reversible
Application
Abrasive/Kiln/Boiler/Power Plant/Sewage Treatment
Start Type
Soft Starter/Frequency Starter
Voltage
380V/440V/660V
Frequency
50Hz/60Hz
Wheel Size
up to 160 Inches (4, 065 mm)
Fan Effect
Air/Smoke Extraction/Ventilation
Dimension
According to Order
Color
Red/White/Grey/Customized
Warranty Period
One Year
Transport Package
Wooden Case
Specification
Centrifugal Blower wooden package
Trademark
Motexo
Origin
China
HS Code
841459
Production Capacity
1000sets Per Month

Product Description

 


 

Motexo Vent--

HEAVY DUTY CENTRIFUGAL FANS

 
APPLICATIONS
 

MTX-VTA series low pressure centrifugal blowers can be used to exclude liquid gas,
industrial plant exhaust, explosion-proof exhaust, automotive industry spray shop exhaust, 
electronic industry dust removal, steel industry blast, fire nuclear power,petrochemical industry, 
waste incineration, C, D with heat sink or Suitable for baking ovens, drying ovens and high
temperature gas circulation in high temperature environments when water is cooled.

 

GENERAL SPECIFICATIONS

 

When the user chooses the boiler pass and the fan, the fan manufacturer shall be informed
of the selection according to the pressure and flow required by the conditions of use.

These blowers are produced for customers special requests.If the customer has other
requirementsfor pressure and air volume what is not included in the following list,
please contact our technicians to design and select the appropriate blower.

 

Standard Parameter Sheet

Pressure Range:176~3344 Pa

Air Volume: 990~43800 m³/h
 

AIRFLOW
SWSI FANS - UP TO 900,000 CFM (1,529,100 M3/HOUR)
DWDI FANS - UP TO 1,500,000 CFM (2,548,500 M3/HOUR)

STATIC PRESSURE
SINGLE-STAGE FANS   - UP TO 120 INCHES W.G. (29,850 PA)
TWO-STAGE FANS        - UP TO 240 INCHES W.G. (59,650 PA)

TEMPERATURE RANGE:  UP TO 1,500°F (815°C)
MOTOR SIZES:  UP TO 15,000 HP (11,185 KW)
ARRANGEMENTS:  1, 3, 7, 8

 

FAN CONSTRUCTIONS


FAN CASING)

The casing is formed from the Q235 steel sheet to stainless steel SS316 or 304 with integral supports.
The grey/red/white/orange paint finish is applied after production, optional hot dip galvanization,
furnace paint or epoxy paint is available. On fan casing there is Aerodynmical round Inlet

 

IMPELLER

Impellers are produced from Q235 Steel Sheet,stainless steel, ZAlSi7Mn Aluminium or FRP.

Static and dynamic vibration defects recovered after production according to appropriate ISO norm.

WHEEL SIZES  UP TO 160 INCHES (4,065 MM)

Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

DRIVEN TYPE
Direct driven,belt driven,coupling driven.

 

OPTIONAL ACCESSORIES

Inlet silencer or outlet silencer,flexible connecter,air shutter.

OUTLET ANGLE
You can check below to select outlet angle that meet your demands.


Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

View more details and technical sheet of our centrifugal fan ,kindly please contact us to get latest catalog.
 

IN-HOUSE MANUFACTURING
  • Impellers in fabricated steel construction
  • Fan shaft machining
  • Qualified welding procedures according to GB norms
  • Virtually no limit to the type of material
 
PRODUCTION DETAILS


Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
 
PRODUCTION WORKSHOP
 

Motexo Fan manufacture 300 series and more than 1,400 kinds of industrial fans.
All include heavy-duty designs for industrial applications.

We have individual workshop for roots blower,centrifugal fans&blowers,
maintaining,axial fan,welding and assembling.


Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace
Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

PRODUCTION&TESTING EQUIPMENT



Not only we can produce large batch of small fan, we have processing capability to produce heavy
duty fans like above 3.5m high. We adopt the best technology in all aspects of industrial fan,
such as shot blasting, sand blasting, all the paint process, welding process, etc.
Stoving vanish looks brighter than water paint( ordinary painting color). It has more than 200 sets of fine,
large and rare processing equipment, and has a high-tech resin sand casting production line.

Our equipment is generally used for power plants, environmental protection plants, coal plants, and so on.
It requires high technology and workmanship.


Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

CUSTOMER CASES

 

Centrifugal Blower Fan Environmental Project Worldwide
We've been working with many project in Uganda,Indonesia, Myanmar,Peru,Pakistan and
other countries for sewage treatment project,Steel plant boiler drafting project,
Hydro Electric Power Plant and tunnel&mining project.
We understand the harsh environments in which fans are used.
Motexo fans will meet and exceed the demands of your industry engineering,
infrastruction project, mining/tunnel project and other environment project.

Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From FurnaceDouble Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace


Centrifugal Fan Equiped with Frequency Control Panel/Soft Starter

Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

DELIVERY & PACKAGE WORLDWIDE

 

For diverse requirements for customers or fans and blowers, we have three methods available
Wooden box, wooden palisade and paper carton.
All package are passing international exported standard.

Double Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From FurnaceDouble Inlet Centrifugal Smoke Exhauster Fan for Suction of Flue Gases From Furnace

 

 

Send your message to this supplier

*From:
*To:
avatar Miss Josslyn
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now