Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

Product Details
Customization: Available
Material: Iron
Usage: for Ventilation
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (6)
  • Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
  • Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
  • Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
  • Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
  • Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
  • Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
Find Similar Products
  • Overview
  • APPLICATIONS
  • GENERAL SPECIFICATIONS
  • FAN CONSTRUCTIONS
  • PRODUCTION DETAILS
  • PRODUCTION WORKSHOP
  • PRODUCTION&TESTING EQUIPMENT
  • CUSTOMER CASES
  • DELIVERY & PACKAGE WORLDWIDE
Overview

Basic Info.

Model NO.
MTX-TFH
Flow Direction
Axial Flow
Pressure
Medium Pressure
Certification
ISO
Air Flow
2.0-83.6m3/S
Outlet Speed
14.7-38m/S
Noise
51-78dB(a)
Speed
2p/4p/6p/8 Pole
Driven Type
Direct Driven
Running Mode
Uni-Directional and Reversible
Application
Hydroelectric Power Plant/Tunnel/Metro Line
Start Type
Soft Starter/Frequency Starter
Voltage
380V/440V/660V
Frequency
50Hz/60Hz
Wheel Size
400-1800mm
Fan Effect
Air/Smoke Extraction/Ventilation
Dimension
According to Order
Color
Red/White/Grey/Customized
Warranty Period
One Year
Transport Package
Wooden Case
Specification
Jet Fan
Trademark
Motexo
Origin
China
HS Code
841459
Production Capacity
1000sets Per Month

Product Description

Motexo Vent--

Jet Fan for Tunnel Ventilation

 
APPLICATIONS
 

Motexo jet fan is mainly used for longitudinal ventilation of roads and railway tunnels,
and can also be used for other similar occasions, such as auxiliary tunnels and sedimentation tanks.

 

GENERAL SPECIFICATIONS

 

TFH series tunnel fan specifications are from 630mm to Ф1600mm, divided into one-way running
axial fan and reversible (two-way) running axial fan. The maximum thrust is 3500N. High efficiency
and low noise can be selected for any load and working condition. 

 

The TFH tunnel fan adopts advanced technology to obtain good quality assurance.
The fan casing adopts the special imported machine tool imported from the United States to form
a rotating flange. The inner wall of the impeller section is processed by gold, which not only ensures
the coaxiality and strength of the casing, but also ensures the radial clearance of the blade.
The surface is hot-dip galvanized, the appearance is beautiful and the anti-corrosion performance
is excellent. The fan blades and the hub are processed into a die-casting cavity by the full CNC
boring and milling center of Toshiba Corporation of Japan, and the aluminum alloy is high in the
high-pressure casting and low-pressure casting machine respectively. (Low) die casting.
Through the actual use of road tunnels, railway tunnels, water conservancy dam projects and
other users, the performance indicators of the wind turbines, corrosion resistance, reliability,
economy and other technical, quality requirements and economic indicators can fully adapt to
the use of various types of tunnels and subways. 

 

These jet fan are produced for customers special requests.If the customer has other
requirementsfor pressure and air volume what is not included in the following list,
please contact our technicians to design and select the appropriate tunnel fan.

 

FAN CONSTRUCTIONS



FAN CASING

The casing is formed from the Q235 steel sheet to stainless steel SS316 or 304 with integral supports.
The grey/red/white/orange paint finish is applied after production, optional hot dip galvanization,
furnace paint or epoxy paint is available. On fan casing there is Aerodynmical Inlet


STRUCTURE DRAWING


Ceiling-Mounted Fan / Axial / Fume Exhaust / VentilationCeiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
 

IMPELLER

Impellers are produced from Q235 Steel Sheet,stainless steel, ZAlSi7Mn Aluminium.

Static and dynamic vibration defects recovered after production according to appropriate
ISO/GB norm.
Wheel Size:  400--1800mm

 

Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
 

DRIVEN TYPE
Direct driven

 

OPTIONAL ACCESSORIES

1D/2D Inlet silencer or 1D/2D outlet silencer,flexible connecter.


View more details and technical sheet of our jet fan ,kindly please contact us to get latest catalog.
 

IN-HOUSE MANUFACTURING
  • Impellers in fabricated steel construction
  • Fan shaft machining
  • Qualified welding procedures according to GB norms
  • Virtually no limit to the type of material
 
PRODUCTION DETAILS


Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

 

PRODUCTION WORKSHOP



Motexo Fan manufacture 300 series and more than 1,400 kinds of industrial fans.
All include heavy-duty designs for industrial applications.

We have individual workshop for roots blower,centrifugal fans&blowers,
maintaining,axial fan,welding and assembling.


Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation
 

PRODUCTION&TESTING EQUIPMENT


Not only we can produce large batch of small fan, we have processing capability to produce heavy
duty fans like above 3.5m high. We adopt the best technology in all aspects of industrial fan,
such as shot blasting, sand blasting, all the paint process, welding process, etc.
Stoving vanish looks brighter than water paint( ordinary painting color). It has more than 200 sets of fine,
large and rare processing equipment, and has a high-tech resin sand casting production line.

Our equipment is generally used for power plants, environmental protection plants, coal plants, and so on.
It requires high technology and workmanship.

Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

FACTORY PRODUCTION CAPACITY:
AIRFLOW
SWSI FANS - UP TO 900,000 CFM (1,529,100 M3/HOUR)
DWDI FANS - UP TO 1,500,000 CFM (2,548,500 M3/HOUR)

STATIC PRESSURE
SINGLE-STAGE FANS   - UP TO 120 INCHES W.G. (29,850 PA)
TWO-STAGE FANS        - UP TO 240 INCHES W.G. (59,650 PA)

TEMPERATURE RANGE:  UP TO 1,500°F (815°C)
MOTOR SIZES:  UP TO 15,000 HP (11,185 KW)
ARRANGEMENTS:  1, 3, 7, 8

WHEEL SIZES  UP TO 160 INCHES (4,065 MM)

 

CUSTOMER CASES



Mining/Metro Line/Tunnel Project Worldwide

We've been working with many project in Uganda,Indonesia, Myanmar,Peru,Pakistan and
other countries for tunnel&mining project,sewage treatment project,Steel plant boiler drafting project
nd Hydro Electric Power Plant.
We understand the harsh environments in which fans are used.
Motexo fans will meet and exceed the demands of your industry engineering,
infrastruction project, mining/tunnel project and other environment project.

Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

 

Jet Fan Equiped with Frequency Control Panel/Soft Starter

Ceiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

 
DELIVERY & PACKAGE WORLDWIDE

 

For diverse requirements for customers or fans and blowers, we have three methods available
Wooden box, wooden palisade and paper carton.
All package are passing international exported standard.

Ceiling-Mounted Fan / Axial / Fume Exhaust / VentilationCeiling-Mounted Fan / Axial / Fume Exhaust / Ventilation

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier